詳細介紹 UL/C-UL , CE ApprovedFeatures1.Multiple functions built inThe operation mode and time range can be switched by using the MODE and RANGE switches on the front panel.2.Part number consolidation1.The lineup consists of 64 easy-to-choosemodels.2.An operation mode fixed type (S1DXM-A) and 4-operation mode switching type (S1DXM-M) are available.3.Cadmium-free contacts usedTo eliminate environmentally harmful chemical substances, relays with cadmium-free contacts are used.4.Economically priced1.Prices set to lower costs.2.Further cost reduction when used with HJ Relay terminal socket.5.CE marking supporteUL and C-UL approved.Operation Mode1.S1DXM-A multi-range timerOperation modePower ON-delay operationWhen power is turned on, the output contact operates after the set time.The output contact remains on until the power is turned off.2.S1DXM-M multi-range timerOperation modePower ON-delay operation[MODE] switch 1: OFF, switch 2: OFF. When power is turned on, the output contact operates after the set time.The output contact remains on until the power is turned off.Power Flicker OFF start operation[MODE] switch 1: OFF, switch 2: ONWhen the power is turned on, the output contacts repeatedly operate at the set time.The output contact begins from the off state.Power Flicker ON start operation[MODE] switch 1: ON, switch 2: OFFWhen power is turned on, the output contact operates repeatedly at the set time.The output contact outputs at the same time power turns on.Power One-shot operation[MODE] switch 1: ON, switch 2: ONWhen power is turned on, the output contact performs the on operation at the same time power turns on, only for the set time.Time range settingTypeTime scaleTime unitMin.scaleMax.scaleSetting rangeS1DXM-A10M type×1×10sm0.0510.05 to 1s0.5 to 10s0.05 to 1m0.5 to 10m30M typesm0.230.2 to 3s2 to 30s0.2 to 3m2 to 30m60M typesm0.560.5 to 6s5 to 60s0.5 to 6m5 to 60m10H typemh0.0510.05 to 1m0.5 to 10m0.05 to 1h0.5 to 10hS1DXM-M10M type×1×10sm0.0510.05 to 1s0.5 to 10s0.05 to 1m0.5 to 10m30M typesm0.230.2 to 3s2 to 30s0.2 to 3m2 to 30m60M typesm0.560.5 to 6s5 to 60s0.5 to 6m5 to 60m10H typemh0.0510.05 to 1m0.5 to 10m0.05 to 1h0.5 to 10h*The time setting range is the combination of the time scale (X1 or X10) on the dial and the time unit (s, m, or h).Example: When dial reads 1,time scale is X1 and time units is seconds, then it is 1 second.Operation Mode and Time Range SettingOperation modePower ON-delayPower Flicker OFF startPower Flicker ON startPower One-shotOperation mode switchTime range switchThe time setting can be switched among 4 ranges each for 4 typesfor an interval between 0.05 seconds and 10 hours.1*The product is factory shipped with all settings on the OFF side (left).2*Do not operate the switches with a sharp-edged object such as a knife blade.3*The power must be turned off when setting the time range or operation mode. Operating the switches with the power on is a cause of breakdown and malfunction.4*Use a force of under 5 N to operate the DIP switches when setting the time range and operation mode.Return to topPart Number1.S1DXM-A Multi-range TimerNo MODE Switch, Operation Mode (Fixed): Power ON-delayOperating voltageTime rangeTimed-out 2 Form CTimed-out 4 Form CPart NumberPart Number12V DC0.05s to 10 minS1DXM-A2C10M-DC12VS1DXM-A4C10M-DC12V0.2 s to 30 minS1DXM-A2C30M-DC12VS1DXM-A4C30M-DC12V0.5 s to 60 minS1DXM-A2C60M-DC12VS1DXM-A4C60M-DC12V0.05 min to 10 hrS1DXM-A2C10H-DC12VS1DXM-A4C10H-DC12V24V DC0.05 s to 10 minS1DXM-A2C10M-DC24VS1DXM-A4C10M-DC24V0.2 s to 30 minS1DXM-A2C30M-DC24VS1DXM-A4C30M-DC24V0.5 s to 60 minS1DXM-A2C60M-DC24VS1DXM-A4C60M-DC24V0.05 min to 10 hrS1DXM-A2C10H-DC24VS1DXM-A4C10H-DC24V100 to 120V AC0.05 s to 10 minS1DXM-A2C10M-AC120VS1DXM-A4C10M-AC120V0.2 s to 30 minS1DXM-A2C30M-AC120VS1DXM-A4C30M-AC120V0.5 s to 60 minS1DXM-A2C60M-AC120VS1DXM-A4C60M-AC120V0.05 min to 10 hrS1DXM-A2C10H-AC120VS1DXM-A4C10H-AC120V200 to 220V AC0.05 s to 10 minS1DXM-A2C10M-AC220VS1DXM-A4C10M-AC220V0.2 s to 30 minS1DXM-A2C30M-AC220VS1DXM-A4C30M-AC220V0.5 s to 60 minS1DXM-A2C60M-AC220VS1DXM-A4C60M-AC220V0.05 min to 10 hrS1DXM-A2C10H-AC220VS1DXM-A4C10H-AC220V2.S1DXM-M Multi-range TimerWith MODE Switch, Operation Mode (Switchable): Power ON-delay, Power Flicker ON Start, Power Flicker OFF Start, Power One-shotOperating voltageTime rangeTimed-out 2 Form CTimed-out 4 Form CPart NumberPart Number12V DC0.05 s to 10 minS1DXM-M2C10M-DC12VS1DXM-M4C10M-DC12V0.2 s to 30 minS1DXM-M2C30M-DC12VS1DXM-M4C30M-DC12V0.5 s to 60 minS1DXM-M2C60M-DC12VS1DXM-M4C60M-DC12V0.05 min to 10 hrS1DXM-M2C10H-DC12VS1DXM-M4C10H-DC12V24V DC0.05 s to 10 minS1DXM-M2C10M-DC24VS1DXM-M4C10M-DC24V0.2 s to 30 minS1DXM-M2C30M-DC24VS1DXM-M4C30M-DC24V0.5 s to 60 minS1DXM-M2C60M-DC24VS1DXM-M4C60M-DC24V0.05 min to 10 hrS1DXM-M2C10H-DC24VS1DXM-M4C10H-DC24V100 to 120V AC0.05 s to 10 minS1DXM-M2C10M-AC120VS1DXM-M4C10M-AC120V0.2 s to 30 minS1DXM-M2C30M-AC120VS1DXM-M4C30M-AC120V0.5 s to 60 minS1DXM-M2C60M-AC120VS1DXM-M4C60M-AC120V0.05 min to 10 hrS1DXM-M2C10H-AC120VS1DXM-M4C10H-AC120V200 to 220V AC0.05 s to 10 minS1DXM-M2C10M-AC220VS1DXM-M4C10M-AC220V0.2 s to 30 minS1DXM-M2C30M-AC220VS1DXM-M4C30M-AC220V0.5 s to 60 minS1DXM-M2C60M-AC220VS1DXM-M4C60M-AC220V0.05 min to 10 hrS1DXM-M2C10H-AC220VS1DXM-M4C10H-AC220VReturn to topOptionS1DXM-A/M/S1DX Common OptionsAccesories(mm inch)Socket leaf holding clip for S1DXTerminal socketmminchAccesoriesMounting frameADX18002 / ADX18002 (Titanium-gray) / ADX18006 (Gray) / ADX18007 (Black)AppearancePanel cutout dimensionsBoard thickness 1 to 3 mmNote)Make sure the holes area stays as right angles.Protective coverADX18008Cap blockADX18011CapADX18004SocketADX18003Return to topSocket Leaf Holding Clip for S1DXADX18012AD68002FigureDimensionsFigureDimensionsSocket lime holding clip for S1DXM-A/MADX28005DimensionsTypeApplicationTerminal socketADX18012AD68002ADX28005For HC relayAP3821-AP3827K-AP3847K-For HJ relayAHJ3821--AHJ38211--AHJ3848--AHJ38481--The triangles indicate that removal will be slightly difficult when installed laterally in succession.Return to topTerminal SocketHC2 slim DIN terminal socketHC2-SFD-SHC2 DIN high terminal socketHC2-SFD-KHC4 DIN high terminal socketHC4-SFD-KHC4 socketHC4-SS-KHJ2 terminal socketHJ2-SFD/HJ2-SFD-SHJ4 terminal socketHJ4-SFD/HJ4-SFD-SHC relay terminal socketsFor general railsName / Part No.Terminal socket, HC 2-pinHC2-SF-KDimensionsNote) Only wire springs can be used.(Plate springs cannot be used.)Terminal layoutMounting hole dimensionsPanel hole dimensions for side-by-side mountingApplicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableNot AvailableName / Part No.Terminal socket, HC 2-pinHC4-HSF-KDimensionsNote) Only wire springs can be used.(Plate springs cannot be used.)Terminal layoutMounting hole dimensionsPanel hole dimensions for side-by-side mountingApplicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableAvailableFor DIN railsName / Part No.Slim DIN terminal socket,HC2HC2-SFD-SDimensionsTerminal layoutMounting hole dimensionsApplicable timersS1DX(2c), S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableNot AvailableHJ relay terminal socketsName / Part No.HJ2h terminal socketHJ2-SFDDimensionsTerminal layoutMounting hole dimensionsApplicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableNot AvailableName / Part No.HJ2h terminal socket(Finger protect type)HJ2-SFD-SDimensionsTerminal layoutMounting hole dimensionsApplicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableNot AvailableName / Part No.HJ4 terminal socketHJ4-SFDDimensionsTerminal layoutMounting hole dimensionsApplicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableAvailableName / Part No.HJ4 terminal socket(Finger protect type)HJ4-SFD-SDimensionsTerminal layoutMounting hole dimensionsDrilling size of panel holes for installing the terminal sockets parallelApplicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableAvailableSocketsName / Part No.Socket HC 2-pin HC2-SS-KDimensionsThe difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.General tolerance: ±0.5 ±.020Mounting hole dimensionsThe thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.Dimensional tolerance of machining: ±0.1 ±.004Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableNot AvailableName / Part No.Socket, HC 4-pin HC4-SS-KDimensionsThe difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same.General tolerance: ±0.5 ±.020Mounting hole dimensionsThe thickness of applicable chassis plates ranges from 1.0 to 2.0 mm .039 to .079 inch.To install the socket easily, insert the socket top surface into the drilled holes and press the two points on the fastening plate indicated by arrows as shown in the fig. below.Dimensional tolerance of machining: ±0.1 ±.004Applicable timersS1DX(2c),S1DXM(2c)S1DX(4c), S1DXM(4c)AvailableAvailable*Sockets for PC boardHC2-Socket for PC board: AP3825KHC4-Socket for PC board: AP3845KReturn to topReturn to topDimensionsUnit: mm in1.S1DXM-A2.S1DXM-M1.S1DXM-AGeneral tolerance : ±0.5 ±0.20Terminal layouts and Wiring diagramTimed-out 2 Form C typeTerminal layouts and Wiring diagramTimed-out 4 Form C type* For the DC operating type, terminal 14 is “+" and terminal 13 is “-".2.S1DXM-MGeneral tolerance : ±0.5 ±0.20Terminal layouts and Wiring diagramTimed-out 2 Form C typeTerminal layouts and Wiring diagramTimed-out 4 Form C type* For the DC operating type, terminal 14 is “+" and terminal 13 is “-".Return to top